configure fan control
This commit is contained in:
parent
4653d2c573
commit
c9e6b105a9
2
hosts
2
hosts
|
@ -31,6 +31,8 @@ all:
|
|||
hosts:
|
||||
router-0:
|
||||
ansible_host: 192.168.10.10
|
||||
server-0:
|
||||
ansible_host: 192.168.10.11
|
||||
# vars:
|
||||
# ansible_user: root
|
||||
lb:
|
||||
|
|
|
@ -1,3 +1,7 @@
|
|||
- hosts: proxmox
|
||||
roles:
|
||||
- proxmox
|
||||
|
||||
- hosts: debian
|
||||
roles:
|
||||
- common
|
||||
|
@ -6,10 +10,6 @@
|
|||
roles:
|
||||
- haproxy
|
||||
|
||||
- hosts: proxmox
|
||||
roles:
|
||||
- proxmox
|
||||
|
||||
- hosts: k3s-server
|
||||
roles:
|
||||
- k3s-server
|
||||
|
|
|
@ -0,0 +1,18 @@
|
|||
SUBSYSTEM=="thermal"
|
||||
KERNEL=="thermal_zone0"
|
||||
|
||||
# If the temp hits 75c, turn on the fan. Turn it off again when it goes back down to 70.
|
||||
ATTR{trip_point_3_temp}="75000"
|
||||
ATTR{trip_point_3_hyst}="5000"
|
||||
#
|
||||
# If the temp hits 78c, higher RPM.
|
||||
ATTR{trip_point_2_temp}="78000"
|
||||
ATTR{trip_point_2_hyst}="2000"
|
||||
#
|
||||
# If the temp hits 80c, higher RPM.
|
||||
ATTR{trip_point_1_temp}="80000"
|
||||
ATTR{trip_point_1_hyst}="2000"
|
||||
#
|
||||
# If the temp hits 81c, highest RPM.
|
||||
ATTR{trip_point_0_temp}="81000"
|
||||
ATTR{trip_point_0_hyst}="5000"
|
|
@ -7,6 +7,12 @@
|
|||
group: root
|
||||
mode: 0755
|
||||
|
||||
- name: Configure poe hat fan speed control udev rules
|
||||
copy:
|
||||
src: 50-rpi-fan.rules
|
||||
dest: /etc/udev/rules.d/50-rpi-fan.rules
|
||||
notify: reboot
|
||||
|
||||
- name: Enable cgroups
|
||||
copy:
|
||||
src: cmdline.txt
|
||||
|
|
|
@ -1,2 +1 @@
|
|||
deb http://download.proxmox.com/debian/pve bullseye pve-no-subscription
|
||||
|
||||
|
|
Loading…
Reference in New Issue