1
0
Fork 0

add snmp-exporter

This commit is contained in:
Massaki Archambault 2023-10-19 23:48:14 -04:00
parent 719ff8189a
commit bb2c1270a2
24 changed files with 38295 additions and 26 deletions

View File

@ -5,7 +5,7 @@ KUBECTL = kubectl
KUBECTLFLAGS =
KUBECTLDIFFFLAGS =
KUBECTLDIFFPRINTER = highlight --out-format xterm256 --syntax diff
KUBECTLAPPLYFLAGS = --prune
KUBECTLAPPLYFLAGS = --prune --server-side --force-conflicts
KUBECTLAPPLYPRINTER = sed -E -e 's/(.+configured)/\o033[32m\1\o033[0m/g' -e 's/(.+pruned)/\o033[31m\1\o033[0m/g'
SRC := $(shell find kustomize/ -type f)

View File

@ -25,14 +25,9 @@ spec:
- name: deluge-daemon
hostPort: 58846
containerPort: 58846
- name: torrent-tcp
- name: torrent
containerPort: 6881
hostPort: 6881
protocol: TCP
- name: torrent-udp
containerPort: 6881
hostPort: 6881
protocol: UDP
resources:
requests:
cpu: 1500m

View File

@ -45,3 +45,14 @@ spec:
name: collabora
port:
name: http
---
# https://docs.nextcloud.com/server/27/admin_manual/issues/general_troubleshooting.html#service-discovery
apiVersion: traefik.containo.us/v1alpha1
kind: Middleware
metadata:
name: server-redirectregex
spec:
redirectRegex:
permanent: true
regex: https://(.*)/.well-known/(?:card|cal)dav
replacement: https://$${1}/remote.php/dav

File diff suppressed because it is too large Load Diff

View File

@ -0,0 +1,11 @@
resources:
- snmp-exporter-deployment.yaml
commonLabels:
app.kubernetes.io/name: snmp-exporter
app.kubernetes.io/part-of: monitoring
configMapGenerator:
- name: exporter-config
files:
- snmp.yml=configurations/snmp.yml

File diff suppressed because it is too large Load Diff

View File

@ -0,0 +1,128 @@
--
-- Copyright (c) 2005-2006
-- Hartmut Brandt
-- All rights reserved.
--
-- Author: Harti Brandt <harti@freebsd.org>
--
-- Redistribution and use in source and binary forms, with or without
-- modification, are permitted provided that the following conditions
-- are met:
-- 1. Redistributions of source code must retain the above copyright
-- notice, this list of conditions and the following disclaimer.
-- 2. Redistributions in binary form must reproduce the above copyright
-- notice, this list of conditions and the following disclaimer in the
-- documentation and/or other materials provided with the distribution.
--
-- THIS SOFTWARE IS PROVIDED BY AUTHOR AND CONTRIBUTORS ``AS IS'' AND
-- ANY EXPRESS OR IMPLIED WARRANTIES, INCLUDING, BUT NOT LIMITED TO, THE
-- IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE
-- ARE DISCLAIMED. IN NO EVENT SHALL AUTHOR OR CONTRIBUTORS BE LIABLE
-- FOR ANY DIRECT, INDIRECT, INCIDENTAL, SPECIAL, EXEMPLARY, OR CONSEQUENTIAL
-- DAMAGES (INCLUDING, BUT NOT LIMITED TO, PROCUREMENT OF SUBSTITUTE GOODS
-- OR SERVICES; LOSS OF USE, DATA, OR PROFITS; OR BUSINESS INTERRUPTION)
-- HOWEVER CAUSED AND ON ANY THEORY OF LIABILITY, WHETHER IN CONTRACT, STRICT
-- LIABILITY, OR TORT (INCLUDING NEGLIGENCE OR OTHERWISE) ARISING IN ANY WAY
-- OUT OF THE USE OF THIS SOFTWARE, EVEN IF ADVISED OF THE POSSIBILITY OF
-- SUCH DAMAGE.
--
-- $FreeBSD$
--
-- Additional stuff for the HOST-RESOURCES MIB.
--
BEGEMOT-HOSTRES-MIB DEFINITIONS ::= BEGIN
IMPORTS
MODULE-IDENTITY, OBJECT-TYPE, TimeTicks
FROM SNMPv2-SMI
begemot
FROM BEGEMOT-MIB;
begemotHostres MODULE-IDENTITY
LAST-UPDATED "200601030000Z"
ORGANIZATION "German Aerospace Center"
CONTACT-INFO
" Hartmut Brandt
Postal: German Aerospace Center
Oberpfaffenhofen
82234 Wessling
Germany
Fax: +49 8153 28 2843
E-mail: harti@freebsd.org"
DESCRIPTION
"The MIB for additional HOST-RESOURCES data."
REVISION "200601030000Z"
DESCRIPTION
"Initial revision."
::= { begemot 202 }
begemotHostresObjects OBJECT IDENTIFIER ::= { begemotHostres 1 }
begemotHrStorageUpdate OBJECT-TYPE
SYNTAX TimeTicks
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The maximum number of ticks the storage table is cached."
DEFVAL { 700 }
::= { begemotHostresObjects 1 }
begemotHrFSUpdate OBJECT-TYPE
SYNTAX TimeTicks
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The maximum number of ticks the FS table is cached."
DEFVAL { 700 }
::= { begemotHostresObjects 2 }
begemotHrDiskStorageUpdate OBJECT-TYPE
SYNTAX TimeTicks
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The maximum number of ticks the disk storage table is cached."
DEFVAL { 300 }
::= { begemotHostresObjects 3 }
begemotHrNetworkUpdate OBJECT-TYPE
SYNTAX TimeTicks
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The maximum number of ticks the network table is cached."
DEFVAL { 700 }
::= { begemotHostresObjects 4 }
begemotHrSWInstalledUpdate OBJECT-TYPE
SYNTAX TimeTicks
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The maximum number of ticks the hrSWInstalledTable is cached."
DEFVAL { 1200 }
::= { begemotHostresObjects 5 }
begemotHrSWRunUpdate OBJECT-TYPE
SYNTAX TimeTicks
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The maximum number of ticks the hrSWRunTable and
hrSWRunPerfTable are cached."
DEFVAL { 300 }
::= { begemotHostresObjects 6 }
begemotHrPkgDir OBJECT-TYPE
SYNTAX OCTET STRING
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The path to the package DB directory."
DEFVAL { "/var/db/pkg" }
::= { begemotHostresObjects 7 }
END

View File

@ -0,0 +1,64 @@
--
-- Copyright (c) 2006
-- Hartmut Brandt
-- All rights reserved.
--
-- Author: Harti Brandt <harti@freebsd.org>
--
-- Redistribution and use in source and binary forms, with or without
-- modification, are permitted provided that the following conditions
-- are met:
-- 1. Redistributions of source code must retain the above copyright
-- notice, this list of conditions and the following disclaimer.
-- 2. Redistributions in binary form must reproduce the above copyright
-- notice, this list of conditions and the following disclaimer in the
-- documentation and/or other materials provided with the distribution.
--
-- THIS SOFTWARE IS PROVIDED BY AUTHOR AND CONTRIBUTORS ``AS IS'' AND
-- ANY EXPRESS OR IMPLIED WARRANTIES, INCLUDING, BUT NOT LIMITED TO, THE
-- IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE
-- ARE DISCLAIMED. IN NO EVENT SHALL AUTHOR OR CONTRIBUTORS BE LIABLE
-- FOR ANY DIRECT, INDIRECT, INCIDENTAL, SPECIAL, EXEMPLARY, OR CONSEQUENTIAL
-- DAMAGES (INCLUDING, BUT NOT LIMITED TO, PROCUREMENT OF SUBSTITUTE GOODS
-- OR SERVICES; LOSS OF USE, DATA, OR PROFITS; OR BUSINESS INTERRUPTION)
-- HOWEVER CAUSED AND ON ANY THEORY OF LIABILITY, WHETHER IN CONTRACT, STRICT
-- LIABILITY, OR TORT (INCLUDING NEGLIGENCE OR OTHERWISE) ARISING IN ANY WAY
-- OUT OF THE USE OF THIS SOFTWARE, EVEN IF ADVISED OF THE POSSIBILITY OF
-- SUCH DAMAGE.
--
-- $Begemot: bsnmp/snmp_mibII/BEGEMOT-IP-MIB.txt,v 1.1 2006/02/14 09:04:18 brandt_h Exp $
--
-- Private MIB for IP stuff.
--
BEGEMOT-IP-MIB DEFINITIONS ::= BEGIN
IMPORTS
MODULE-IDENTITY
FROM SNMPv2-SMI
begemot
FROM BEGEMOT-MIB;
begemotIp MODULE-IDENTITY
LAST-UPDATED "200602130000Z"
ORGANIZATION "German Aerospace Center"
CONTACT-INFO
" Hartmut Brandt
Postal: German Aerospace Center
Oberpfaffenhofen
82234 Wessling
Germany
Fax: +49 8153 28 2843
E-mail: harti@freebsd.org"
DESCRIPTION
"The MIB for IP stuff that is not in the official IP MIBs."
REVISION "200602130000Z"
DESCRIPTION
"Initial revision."
::= { begemot 3 }
begemotIpObjects OBJECT IDENTIFIER ::= { begemotIp 1 }
END

View File

@ -0,0 +1,160 @@
--
-- Copyright (c) 2014 Luiz Otavio O Souza <loos@FreeBSD.org>
-- All rights reserved.
--
-- Redistribution and use in source and binary forms, with or without
-- modification, are permitted provided that the following conditions
-- are met:
-- 1. Redistributions of source code must retain the above copyright
-- notice, this list of conditions and the following disclaimer.
-- 2. Redistributions in binary form must reproduce the above copyright
-- notice, this list of conditions and the following disclaimer in the
-- documentation and/or other materials provided with the distribution.
--
-- THIS SOFTWARE IS PROVIDED BY THE REGENTS AND CONTRIBUTORS ``AS IS'' AND
-- ANY EXPRESS OR IMPLIED WARRANTIES, INCLUDING, BUT NOT LIMITED TO, THE
-- IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE
-- ARE DISCLAIMED. IN NO EVENT SHALL THE REGENTS OR CONTRIBUTORS BE LIABLE
-- FOR ANY DIRECT, INDIRECT, INCIDENTAL, SPECIAL, EXEMPLARY, OR CONSEQUENTIAL
-- DAMAGES (INCLUDING, BUT NOT LIMITED TO, PROCUREMENT OF SUBSTITUTE GOODS
-- OR SERVICES; LOSS OF USE, DATA, OR PROFITS; OR BUSINESS INTERRUPTION)
-- HOWEVER CAUSED AND ON ANY THEORY OF LIABILITY, WHETHER IN CONTRACT, STRICT
-- LIABILITY, OR TORT (INCLUDING NEGLIGENCE OR OTHERWISE) ARISING IN ANY WAY
-- OUT OF THE USE OF THIS SOFTWARE, EVEN IF ADVISED OF THE POSSIBILITY OF
-- SUCH DAMAGE.
--
-- $FreeBSD$
--
BEGEMOT-LM75-MIB DEFINITIONS ::= BEGIN
IMPORTS
MODULE-IDENTITY, OBJECT-TYPE, NOTIFICATION-TYPE,
Counter64, Integer32
FROM SNMPv2-SMI
TEXTUAL-CONVENTION, RowStatus
FROM SNMPv2-TC
begemot
FROM BEGEMOT-MIB;
begemotLoos MODULE-IDENTITY
LAST-UPDATED "201402240000Z"
ORGANIZATION "FreeBSD"
CONTACT-INFO
" Luiz Otavio O Souza
Postal: N/A
Fax: N/A
E-Mail: loos@FreeBSD.org"
DESCRIPTION
"The Begemot MIB for reading lm75 sensors data."
REVISION "201402240000Z"
DESCRIPTION
"Initial revision."
::= { begemot 400 }
begemotLm75Objects OBJECT IDENTIFIER ::= { begemotLm75 1 }
-- ---------------------------------------------------------- --
-- Configuration parameters
-- ---------------------------------------------------------- --
lm75Sensor OBJECT IDENTIFIER ::= { begemotlm75Objects 1 }
lm75Sensors OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Number of LM75 sensors in the system."
::= { lm75Sensors 1 }
-- ---------------------------------------------------------- --
-- TempSensor Table
-- ---------------------------------------------------------- --
lm75SensorTable OBJECT-TYPE
SYNTAX SEQUENCE OF Lm75SensorEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A table containing information about all temperature sensors."
::= { begemotLm75Objects 2 }
loosTempSensorEntry OBJECT-TYPE
SYNTAX Lm75SensorEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Table entry that describes one temperature sensor."
INDEX { lm75SensorIndex }
::= { lm75SensorTable 1 }
Lm75SensorEntry ::= SEQUENCE {
lm75SensorIndex Integer32,
lm75SensorSysctlIndex Integer32,
lm75SensorDesc OCTET STRING,
lm75SensorLocation OCTET STRING,
lm75SensorPnpInfo OCTET STRING,
lm75SensorParent OCTET STRING,
lm75SensorTemperature Integer32
}
lm75SensorIndex OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"LM75 Sensor index."
::= { lm75SensorEntry 1 }
lm75SensorSysctlIndex OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"LM75 Sensor sysctl index."
::= { lm75SensorEntry 2 }
lm75SensorDesc OBJECT-TYPE
SYNTAX OCTET STRING
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"LM75 Sensor description."
::= { lm75SensorEntry 3 }
lm75SensorLocation OBJECT-TYPE
SYNTAX OCTET STRING
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"LM75 Sensor location."
::= { lm75SensorEntry 4 }
lm75SensorPnpInfo OBJECT-TYPE
SYNTAX OCTET STRING
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"LM75 Sensor pnp information."
::= { lm75SensorEntry 5 }
lm75SensorParent OBJECT-TYPE
SYNTAX OCTET STRING
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"LM75 Sensor parent bus."
::= { lm75SensorEntry 6 }
lm75SensorTemperature OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"LM75 Sensor temperature."
::= { lm75SensorEntry 7 }
END

View File

@ -0,0 +1,62 @@
--
-- Copyright (c) 2001-2003
-- Fraunhofer Institute for Open Communication Systems (FhG Fokus).
-- All rights reserved.
--
-- Author: Harti Brandt <harti@freebsd.org>
--
-- Redistribution and use in source and binary forms, with or without
-- modification, are permitted provided that the following conditions
-- are met:
-- 1. Redistributions of source code must retain the above copyright
-- notice, this list of conditions and the following disclaimer.
-- 2. Redistributions in binary form must reproduce the above copyright
-- notice, this list of conditions and the following disclaimer in the
-- documentation and/or other materials provided with the distribution.
--
-- THIS SOFTWARE IS PROVIDED BY AUTHOR AND CONTRIBUTORS ``AS IS'' AND
-- ANY EXPRESS OR IMPLIED WARRANTIES, INCLUDING, BUT NOT LIMITED TO, THE
-- IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE
-- ARE DISCLAIMED. IN NO EVENT SHALL AUTHOR OR CONTRIBUTORS BE LIABLE
-- FOR ANY DIRECT, INDIRECT, INCIDENTAL, SPECIAL, EXEMPLARY, OR CONSEQUENTIAL
-- DAMAGES (INCLUDING, BUT NOT LIMITED TO, PROCUREMENT OF SUBSTITUTE GOODS
-- OR SERVICES; LOSS OF USE, DATA, OR PROFITS; OR BUSINESS INTERRUPTION)
-- HOWEVER CAUSED AND ON ANY THEORY OF LIABILITY, WHETHER IN CONTRACT, STRICT
-- LIABILITY, OR TORT (INCLUDING NEGLIGENCE OR OTHERWISE) ARISING IN ANY WAY
-- OUT OF THE USE OF THIS SOFTWARE, EVEN IF ADVISED OF THE POSSIBILITY OF
-- SUCH DAMAGE.
--
-- $Begemot: bsnmp/snmpd/BEGEMOT-MIB.txt,v 1.5 2004/08/06 08:47:07 brandt Exp $
--
-- Begemot private definitions and root.
--
BEGEMOT-MIB DEFINITIONS ::= BEGIN
IMPORTS
MODULE-IDENTITY
FROM SNMPv2-SMI
fokus
FROM FOKUS-MIB;
begemot MODULE-IDENTITY
LAST-UPDATED "200201300000Z"
ORGANIZATION "Fraunhofer FOKUS, CATS"
CONTACT-INFO
" Hartmut Brandt
Postal: Fraunhofer Institute for Open Communication Systems
Kaiserin-Augusta-Allee 31
10589 Berlin
Germany
Fax: +49 30 3463 7352
E-mail: harti@freebsd.org"
DESCRIPTION
"The root of the Begemot subtree of the fokus tree."
REVISION "200201300000Z"
DESCRIPTION
"Initial revision."
::= { fokus 1 }
END

View File

@ -0,0 +1,106 @@
--
-- Copyright (c) 2006
-- Hartmut Brandt
-- All rights reserved.
--
-- Author: Harti Brandt <harti@freebsd.org>
--
-- Redistribution and use in source and binary forms, with or without
-- modification, are permitted provided that the following conditions
-- are met:
-- 1. Redistributions of source code must retain the above copyright
-- notice, this list of conditions and the following disclaimer.
-- 2. Redistributions in binary form must reproduce the above copyright
-- notice, this list of conditions and the following disclaimer in the
-- documentation and/or other materials provided with the distribution.
--
-- THIS SOFTWARE IS PROVIDED BY AUTHOR AND CONTRIBUTORS ``AS IS'' AND
-- ANY EXPRESS OR IMPLIED WARRANTIES, INCLUDING, BUT NOT LIMITED TO, THE
-- IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE
-- ARE DISCLAIMED. IN NO EVENT SHALL AUTHOR OR CONTRIBUTORS BE LIABLE
-- FOR ANY DIRECT, INDIRECT, INCIDENTAL, SPECIAL, EXEMPLARY, OR CONSEQUENTIAL
-- DAMAGES (INCLUDING, BUT NOT LIMITED TO, PROCUREMENT OF SUBSTITUTE GOODS
-- OR SERVICES; LOSS OF USE, DATA, OR PROFITS; OR BUSINESS INTERRUPTION)
-- HOWEVER CAUSED AND ON ANY THEORY OF LIABILITY, WHETHER IN CONTRACT, STRICT
-- LIABILITY, OR TORT (INCLUDING NEGLIGENCE OR OTHERWISE) ARISING IN ANY WAY
-- OUT OF THE USE OF THIS SOFTWARE, EVEN IF ADVISED OF THE POSSIBILITY OF
-- SUCH DAMAGE.
--
-- $Begemot: bsnmp/snmp_mibII/BEGEMOT-MIB2-MIB.txt,v 1.1 2006/02/14 09:04:18 brandt_h Exp $
--
-- Private MIB for MIB2.
--
BEGEMOT-MIB2-MIB DEFINITIONS ::= BEGIN
IMPORTS
MODULE-IDENTITY, OBJECT-TYPE, TimeTicks, Counter64
FROM SNMPv2-SMI
begemotIp
FROM BEGEMOT-IP-MIB;
begemotMib2 MODULE-IDENTITY
LAST-UPDATED "200908030000Z"
ORGANIZATION "German Aerospace Center"
CONTACT-INFO
" Hartmut Brandt
Postal: German Aerospace Center
Oberpfaffenhofen
82234 Wessling
Germany
Fax: +49 8153 28 2843
E-mail: harti@freebsd.org"
DESCRIPTION
"The MIB for private mib2 stuff."
REVISION "200908030000Z"
DESCRIPTION
"Second edition adds begemotIfDataPoll object."
REVISION "200602130000Z"
DESCRIPTION
"Initial revision."
::= { begemotIp 1 }
begemotIfMaxspeed OBJECT-TYPE
SYNTAX Counter64
UNITS "bps"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The speed of the fastest interface in ifTable in bps."
::= { begemotMib2 1 }
begemotIfPoll OBJECT-TYPE
SYNTAX TimeTicks
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The current polling rate for the HC 64-bit counters."
::= { begemotMib2 2 }
begemotIfForcePoll OBJECT-TYPE
SYNTAX TimeTicks
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The polling rate to be enforced for the HC 64-bit counters.
If this value is 0 the mib2 module computes a polling rate
depending on the value of begemotIfMaxspeed. If this value
turns out to be wrong, the polling rate can be force to an
arbitrary value by setting begemotIfForcePoll to a non-0
value. This may be necessary if an interface announces a wrong
bit rate in its MIB."
::= { begemotMib2 3 }
begemotIfDataPoll OBJECT-TYPE
SYNTAX TimeTicks
UNITS "deciseconds"
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The rate at which the mib2 module will poll interface data."
DEFVAL { 100 }
::= { begemotMib2 4 }
END

View File

@ -0,0 +1,411 @@
--
-- Copyright (c) 2001-2003
-- Fraunhofer Institute for Open Communication Systems (FhG Fokus).
-- All rights reserved.
--
-- Author: Harti Brandt <harti@freebsd.org>
--
-- Redistribution of this software and documentation and use in source and
-- binary forms, with or without modification, are permitted provided that
-- the following conditions are met:
--
-- 1. Redistributions of source code or documentation must retain the above
-- copyright notice, this list of conditions and the following disclaimer.
-- 2. Redistributions in binary form must reproduce the above copyright
-- notice, this list of conditions and the following disclaimer in the
-- documentation and/or other materials provided with the distribution.
--
-- THIS SOFTWARE AND DOCUMENTATION IS PROVIDED BY FRAUNHOFER FOKUS
-- AND ITS CONTRIBUTORS ``AS IS'' AND ANY EXPRESS OR IMPLIED WARRANTIES,
-- INCLUDING, BUT NOT LIMITED TO, THE IMPLIED WARRANTIES OF MERCHANTABILITY AND
-- FITNESS FOR A PARTICULAR PURPOSE ARE DISCLAIMED. IN NO EVENT SHALL
-- FRAUNHOFER FOKUS OR ITS CONTRIBUTORS BE LIABLE FOR ANY DIRECT, INDIRECT,
-- INCIDENTAL, SPECIAL, EXEMPLARY, OR CONSEQUENTIAL DAMAGES (INCLUDING, BUT NOT
-- LIMITED TO, PROCUREMENT OF SUBSTITUTE GOODS OR SERVICES; LOSS OF USE, DATA,
-- OR PROFITS; OR BUSINESS INTERRUPTION) HOWEVER CAUSED AND ON ANY THEORY OF
-- LIABILITY, WHETHER IN CONTRACT, STRICT LIABILITY, OR TORT (INCLUDING
-- NEGLIGENCE OR OTHERWISE) ARISING IN ANY WAY OUT OF THE USE OF THIS SOFTWARE,
-- EVEN IF ADVISED OF THE POSSIBILITY OF SUCH DAMAGE.
--
-- $FreeBSD$
--
-- Private MIB for netgraph part of Begemot SNMP daemon.
--
BEGEMOT-NETGRAPH-MIB DEFINITIONS ::= BEGIN
IMPORTS
MODULE-IDENTITY, OBJECT-TYPE, Counter32, Unsigned32
FROM SNMPv2-SMI
TEXTUAL-CONVENTION, TruthValue
FROM SNMPv2-TC
MODULE-COMPLIANCE, OBJECT-GROUP
FROM SNMPv2-CONF
begemot
FROM BEGEMOT-MIB;
begemotNg MODULE-IDENTITY
LAST-UPDATED "200311140000Z"
ORGANIZATION "Fraunhofer FOKUS, CATS"
CONTACT-INFO
" Hartmut Brandt
Postal: Fraunhofer Institute for Open Communication Systems
Kaiserin-Augusta-Allee 31
10589 Berlin
Germany
Fax: +49 30 3463 7352
E-mail: harti@freebsd.org"
DESCRIPTION
"The MIB for the NetGraph access module for SNMP."
REVISION "200311140000Z"
DESCRIPTION
"The maximum width of the following OCTET STRINGs was increased
from 15 to 31:
- NgTypeName
- NgNodeName
- NgNodeNameOrEmpty
- NgHookName
"
REVISION "200201310000Z"
DESCRIPTION
"Initial revision."
::= { begemot 2 }
begemotNgObjects OBJECT IDENTIFIER ::= { begemotNg 1 }
-- --------------------------------------------------------------------------
NgTypeName ::= TEXTUAL-CONVENTION
DISPLAY-HINT "31a"
STATUS current
DESCRIPTION
"Name of a netgraph type."
SYNTAX OCTET STRING (SIZE(1..31))
NgNodeName ::= TEXTUAL-CONVENTION
DISPLAY-HINT "31a"
STATUS current
DESCRIPTION
"Name of a netgraph node."
SYNTAX OCTET STRING (SIZE(1..31))
NgNodeNameOrEmpty ::= TEXTUAL-CONVENTION
DISPLAY-HINT "31a"
STATUS current
DESCRIPTION
"Name of a netgraph node."
SYNTAX OCTET STRING (SIZE(0..31))
NgHookName ::= TEXTUAL-CONVENTION
DISPLAY-HINT "31a"
STATUS current
DESCRIPTION
"Name of a netgraph hook."
SYNTAX OCTET STRING (SIZE(1..31))
NgNodeId ::= TEXTUAL-CONVENTION
DISPLAY-HINT "x"
STATUS current
DESCRIPTION
"Node identifier."
SYNTAX Unsigned32 (1..4294967295)
NgNodeIdOrZero ::= TEXTUAL-CONVENTION
DISPLAY-HINT "x"
STATUS current
DESCRIPTION
"Node identifier or 0 for 'no-node'."
SYNTAX Unsigned32 (0..4294967295)
-- --------------------------------------------------------------------------
--
-- Configuration parameters
--
begemotNgConfig OBJECT IDENTIFIER ::= { begemotNgObjects 1 }
begemotNgControlNodeName OBJECT-TYPE
SYNTAX NgNodeName
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The name of the netgraph node of this daemon. The name is
writeable during initialisation. If the name is set from
the empty string to the non-empty string, the netgraph socket
is created. Once set it cannot be changed."
::= { begemotNgConfig 1 }
begemotNgResBufSiz OBJECT-TYPE
SYNTAX INTEGER (1024..65536)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The size of the receive buffers for netgraph messages."
DEFVAL { 20000 }
::= { begemotNgConfig 2 }
begemotNgTimeout OBJECT-TYPE
SYNTAX INTEGER (10..10000)
UNITS "milliseconds"
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The maximum time to wait for a response to a netgraph message."
DEFVAL { 1000 }
::= { begemotNgConfig 3 }
begemotNgDebugLevel OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The netgraph library debug level. This should be set only
if the daemon is run with a terminal attached."
DEFVAL { 0 }
::= { begemotNgConfig 4 }
-- --------------------------------------------------------------------------
--
-- The STATISTICS Group
--
begemotNgStats OBJECT IDENTIFIER ::= { begemotNgObjects 2 }
begemotNgNoMems OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Number of times a memory allocation has failed for buffers
or the message queue."
::= { begemotNgStats 1 }
begemotNgMsgReadErrs OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Number of times reading a netgraph message has failed."
::= { begemotNgStats 2 }
begemotNgTooLargeMsgs OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Number of times a netgraph message was too large for
the buffer. Try increasing begemotNgResBufSiz if
this happens."
::= { begemotNgStats 3 }
begemotNgDataReadErrs OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Number of times reading a netgraph data message has failed."
::= { begemotNgStats 4 }
begemotNgTooLargeDatas OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Number of times a netgraph data message was too large.
You need to increase begemotNgResBufSiz."
::= { begemotNgStats 5 }
-- -----------------------------------------------------
--
-- The NODE table
--
begemotNgTypeTable OBJECT-TYPE
SYNTAX SEQUENCE OF BegemotNgTypeEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A table containing information about all netgraph node types."
::= { begemotNgObjects 3 }
begemotNgTypeEntry OBJECT-TYPE
SYNTAX BegemotNgTypeEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Table entry that describes one netgraph node."
INDEX { begemotNgTypeName }
::= { begemotNgTypeTable 1 }
BegemotNgTypeEntry ::= SEQUENCE {
begemotNgTypeName NgTypeName,
begemotNgTypeStatus INTEGER
}
begemotNgTypeName OBJECT-TYPE
SYNTAX NgTypeName
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The name of the type. Used as index."
::= { begemotNgTypeEntry 1 }
begemotNgTypeStatus OBJECT-TYPE
SYNTAX INTEGER { loaded(1), unloaded(2) }
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"If loaded then the node type is available. A type can be load
by setting this field to loaded. It is unload if the field is
set to unloaded. Note, that a type cannot be unloaded if it
is compiled into the kernel or has nodes of this type. The name
of the file containing the type implementation is constructed by
prepending ng_ to the type name."
::= { begemotNgTypeEntry 2 }
--
-- Node table
--
begemotNgNodeTable OBJECT-TYPE
SYNTAX SEQUENCE OF BegemotNgNodeEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A table containing information about all netgraph nodes."
::= { begemotNgObjects 4 }
begemotNgNodeEntry OBJECT-TYPE
SYNTAX BegemotNgNodeEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Table entry that describes one netgraph node."
INDEX { begemotNgNodeId }
::= { begemotNgNodeTable 1 }
BegemotNgNodeEntry ::= SEQUENCE {
begemotNgNodeId NgNodeId,
begemotNgNodeStatus INTEGER,
begemotNgNodeName NgNodeNameOrEmpty,
begemotNgNodeType NgTypeName,
begemotNgNodeHooks Unsigned32
}
begemotNgNodeId OBJECT-TYPE
SYNTAX NgNodeId
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The 32bit node id of this node. 0 is an illegal value."
::= { begemotNgNodeEntry 1 }
begemotNgNodeStatus OBJECT-TYPE
SYNTAX INTEGER { valid(1), invalid(2) }
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Indicates whether the node exists or not."
::= { begemotNgNodeEntry 2 }
begemotNgNodeName OBJECT-TYPE
SYNTAX NgNodeNameOrEmpty
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Name of the node (if any)."
::= { begemotNgNodeEntry 3 }
begemotNgNodeType OBJECT-TYPE
SYNTAX NgTypeName
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Type name of the node."
::= { begemotNgNodeEntry 4 }
begemotNgNodeHooks OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Number of hooks on this node."
::= { begemotNgNodeEntry 5 }
--
-- Hook table
--
begemotNgHookTable OBJECT-TYPE
SYNTAX SEQUENCE OF BegemotNgHookEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A table containing information about all netgraph hooks."
::= { begemotNgObjects 5 }
begemotNgHookEntry OBJECT-TYPE
SYNTAX BegemotNgHookEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Table entry that describes one netgraph node."
INDEX { begemotNgHookNodeId, begemotNgHookHook }
::= { begemotNgHookTable 1 }
BegemotNgHookEntry ::= SEQUENCE {
begemotNgHookNodeId NgNodeId,
begemotNgHookHook NgHookName,
begemotNgHookStatus INTEGER,
begemotNgHookPeerNodeId NgNodeId,
begemotNgHookPeerHook NgHookName,
begemotNgHookPeerType NgTypeName
}
begemotNgHookNodeId OBJECT-TYPE
SYNTAX NgNodeId
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The 32bit node id of this node."
::= { begemotNgHookEntry 1 }
begemotNgHookHook OBJECT-TYPE
SYNTAX NgHookName
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Name of the hook."
::= { begemotNgHookEntry 2 }
begemotNgHookStatus OBJECT-TYPE
SYNTAX INTEGER { valid(1), invalid(2) }
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Indicates whether the hook exists or not."
::= { begemotNgHookEntry 3 }
begemotNgHookPeerNodeId OBJECT-TYPE
SYNTAX NgNodeId
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The 32bit node id of the peer node of this hook."
::= { begemotNgHookEntry 4 }
begemotNgHookPeerHook OBJECT-TYPE
SYNTAX NgHookName
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Name of the peer hook."
::= { begemotNgHookEntry 5 }
begemotNgHookPeerType OBJECT-TYPE
SYNTAX NgTypeName
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Name of the peer type."
::= { begemotNgHookEntry 6 }
END

File diff suppressed because it is too large Load Diff

View File

@ -0,0 +1,691 @@
--
-- Copyright (c) 2001-2003
-- Fraunhofer Institute for Open Communication Systems (FhG Fokus).
-- All rights reserved.
--
-- Copyright (c) 2018
-- Hartmut Brandt.
-- All rights reserved.
--
-- Author: Harti Brandt <harti@freebsd.org>
--
-- Redistribution and use in source and binary forms, with or without
-- modification, are permitted provided that the following conditions
-- are met:
-- 1. Redistributions of source code must retain the above copyright
-- notice, this list of conditions and the following disclaimer.
-- 2. Redistributions in binary form must reproduce the above copyright
-- notice, this list of conditions and the following disclaimer in the
-- documentation and/or other materials provided with the distribution.
--
-- THIS SOFTWARE IS PROVIDED BY AUTHOR AND CONTRIBUTORS ``AS IS'' AND
-- ANY EXPRESS OR IMPLIED WARRANTIES, INCLUDING, BUT NOT LIMITED TO, THE
-- IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE
-- ARE DISCLAIMED. IN NO EVENT SHALL AUTHOR OR CONTRIBUTORS BE LIABLE
-- FOR ANY DIRECT, INDIRECT, INCIDENTAL, SPECIAL, EXEMPLARY, OR CONSEQUENTIAL
-- DAMAGES (INCLUDING, BUT NOT LIMITED TO, PROCUREMENT OF SUBSTITUTE GOODS
-- OR SERVICES; LOSS OF USE, DATA, OR PROFITS; OR BUSINESS INTERRUPTION)
-- HOWEVER CAUSED AND ON ANY THEORY OF LIABILITY, WHETHER IN CONTRACT, STRICT
-- LIABILITY, OR TORT (INCLUDING NEGLIGENCE OR OTHERWISE) ARISING IN ANY WAY
-- OUT OF THE USE OF THIS SOFTWARE, EVEN IF ADVISED OF THE POSSIBILITY OF
-- SUCH DAMAGE.
--
-- $Begemot: bsnmp/snmpd/BEGEMOT-SNMPD.txt,v 1.23 2004/08/06 08:47:08 brandt Exp $
--
-- Begemot Private SNMPd MIB.
--
BEGEMOT-SNMPD-MIB DEFINITIONS ::= BEGIN
IMPORTS
MODULE-IDENTITY, OBJECT-TYPE, OBJECT-IDENTITY, Counter32,
Integer32, Unsigned32, IpAddress
FROM SNMPv2-SMI
TEXTUAL-CONVENTION, TruthValue, RowStatus
FROM SNMPv2-TC
InetAddressType, InetAddress, InetPortNumber
FROM INET-ADDRESS-MIB
begemot
FROM BEGEMOT-MIB;
begemotSnmpd MODULE-IDENTITY
LAST-UPDATED "201808080000Z"
ORGANIZATION "Fraunhofer FOKUS, CATS"
CONTACT-INFO
" Hartmut Brandt
Postal: Fraunhofer Institute for Open Communication Systems
Kaiserin-Augusta-Allee 31
10589 Berlin
Germany
Fax: +49 30 3463 7352
E-mail: harti@freebsd.org"
DESCRIPTION
"The MIB module for the Begemot SNMP daemon."
REVISION "201808080000Z"
DESCRIPTION
"Add the begemotSnmpdTransInetTable."
::= { begemot 1 }
begemotSnmpdObjects OBJECT IDENTIFIER ::= { begemotSnmpd 1 }
begemotSnmpdDefs OBJECT IDENTIFIER ::= { begemotSnmpd 2 }
-- --------------------------------------------------------------------------
SectionName ::= TEXTUAL-CONVENTION
DISPLAY-HINT "14a"
STATUS current
DESCRIPTION
"Name of a loadable module. Should consist of alphanumeric characers
only, the first character must be a letter."
SYNTAX OCTET STRING (SIZE(1..14))
-- --------------------------------------------------------------------------
--
-- Agent types
--
begemotSnmpdAgent OBJECT IDENTIFIER ::= { begemotSnmpdDefs 1 }
begemotSnmpdAgentFreeBSD OBJECT-IDENTITY
STATUS current
DESCRIPTION
"Identifies the agent as running on FreeBSD."
::= { begemotSnmpdAgent 1 }
-- --------------------------------------------------------------------------
--
-- The Config Group
--
begemotSnmpdConfig OBJECT IDENTIFIER ::= { begemotSnmpdObjects 1 }
begemotSnmpdTransmitBuffer OBJECT-TYPE
SYNTAX Integer32 (484..65535)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The size of the receive buffer in bytes. Larger messages
are dropped by SNMPd."
DEFVAL { 2048 }
::= { begemotSnmpdConfig 1 }
begemotSnmpdReceiveBuffer OBJECT-TYPE
SYNTAX Integer32 (484..65535)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The size of the transmit buffer in bytes. Larger messages
cannot be sent by the SNMPd."
DEFVAL { 2048 }
::= { begemotSnmpdConfig 2 }
begemotSnmpdCommunityDisable OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Disables all access to the CommunityTable from SNMP. Once
set it cannot be cleared."
DEFVAL { false }
::= { begemotSnmpdConfig 3 }
begemotSnmpdTrap1Addr OBJECT-TYPE
SYNTAX IpAddress
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The trap sink for v1 traps."
::= { begemotSnmpdConfig 4 }
begemotSnmpdVersionEnable OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The SNMP versions that the agent processes. The following
bits are defined:
0x00000001 - SNMPv1
0x00000002 - SNMPv2c
0x00000004 - SNMPv3"
DEFVAL { 3 }
::= { begemotSnmpdConfig 5 }
--
-- Trap destinations
--
begemotTrapSinkTable OBJECT-TYPE
SYNTAX SEQUENCE OF BegemotTrapSinkEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A table with destinations for standard traps."
INDEX { begemotTrapSinkAddr, begemotTrapSinkPort }
::= { begemotSnmpdObjects 2 }
begemotTrapSinkEntry OBJECT-TYPE
SYNTAX BegemotTrapSinkEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Entry describes one trap destination."
INDEX { begemotTrapSinkAddr, begemotTrapSinkPort }
::= { begemotTrapSinkTable 1 }
BegemotTrapSinkEntry ::= SEQUENCE {
begemotTrapSinkAddr IpAddress,
begemotTrapSinkPort INTEGER,
begemotTrapSinkStatus RowStatus
}
begemotTrapSinkAddr OBJECT-TYPE
SYNTAX IpAddress
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Destination IP address of the manager station where to send
traps."
::= { begemotTrapSinkEntry 1 }
begemotTrapSinkPort OBJECT-TYPE
SYNTAX Integer32 (1..65535)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Destination UDP port of the manager station where to send
traps."
::= { begemotTrapSinkEntry 2 }
begemotTrapSinkStatus OBJECT-TYPE
SYNTAX RowStatus
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"Used to create/activate/destroy the entry."
::= { begemotTrapSinkEntry 3 }
--
-- SNMP port table
--
begemotSnmpdPortTable OBJECT-TYPE
SYNTAX SEQUENCE OF BegemotSnmpdPortEntry
MAX-ACCESS not-accessible
STATUS deprecated
DESCRIPTION
"A table with descriptions of UDP ports to listen on
for SNMP messages."
::= { begemotSnmpdObjects 4 }
begemotSnmpdPortEntry OBJECT-TYPE
SYNTAX BegemotSnmpdPortEntry
MAX-ACCESS not-accessible
STATUS deprecated
DESCRIPTION
"An entry in the table with descriptions of UDP ports to
listen on for SNMP messages."
INDEX { begemotSnmpdPortAddress, begemotSnmpdPortPort }
::= { begemotSnmpdPortTable 1 }
BegemotSnmpdPortEntry ::= SEQUENCE {
begemotSnmpdPortAddress IpAddress,
begemotSnmpdPortPort INTEGER,
begemotSnmpdPortStatus INTEGER
}
begemotSnmpdPortAddress OBJECT-TYPE
SYNTAX IpAddress
MAX-ACCESS not-accessible
STATUS deprecated
DESCRIPTION
"The IP address to bind to."
::= { begemotSnmpdPortEntry 1 }
begemotSnmpdPortPort OBJECT-TYPE
SYNTAX Integer32 (1..65535)
MAX-ACCESS not-accessible
STATUS deprecated
DESCRIPTION
"The UDP port to listen on for SNMP messages."
::= { begemotSnmpdPortEntry 2 }
begemotSnmpdPortStatus OBJECT-TYPE
SYNTAX INTEGER { valid(1), invalid(2) }
MAX-ACCESS read-create
STATUS deprecated
DESCRIPTION
"Set status to 1 to create entry, set it to 2 to delete it."
::= { begemotSnmpdPortEntry 3 }
---
--- Community table
---
begemotSnmpdCommunityTable OBJECT-TYPE
SYNTAX SEQUENCE OF BegemotSnmpdCommunityEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A table with the community strings for access control."
::= { begemotSnmpdObjects 5 }
begemotSnmpdCommunityEntry OBJECT-TYPE
SYNTAX BegemotSnmpdCommunityEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A table with the community strings for access control.
When begemotSnmpdCommDisable is true, this table disappears."
INDEX { begemotSnmpdCommunityModule, begemotSnmpdCommunityIndex }
::= { begemotSnmpdCommunityTable 1 }
BegemotSnmpdCommunityEntry ::= SEQUENCE {
begemotSnmpdCommunityModule SectionName,
begemotSnmpdCommunityIndex Unsigned32,
begemotSnmpdCommunityString OCTET STRING,
begemotSnmpdCommunityDescr OCTET STRING,
begemotSnmpdCommunityPermission Unsigned32
}
begemotSnmpdCommunityModule OBJECT-TYPE
SYNTAX SectionName
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Index of the module that has registered this community.
For global communities this is the empty string."
::= { begemotSnmpdCommunityEntry 1 }
begemotSnmpdCommunityIndex OBJECT-TYPE
SYNTAX Unsigned32 (1..4294967295)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The numerical index of the community (private to the module)."
::= { begemotSnmpdCommunityEntry 2 }
begemotSnmpdCommunityString OBJECT-TYPE
SYNTAX OCTET STRING
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The string for access to SNMPd."
::= { begemotSnmpdCommunityEntry 3 }
begemotSnmpdCommunityDescr OBJECT-TYPE
SYNTAX OCTET STRING
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"A description what this community is good for."
::= { begemotSnmpdCommunityEntry 4 }
begemotSnmpdCommunityPermission OBJECT-TYPE
SYNTAX Unsigned32 (1..4294967295)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The numerical value of access rights granted to the community."
::= { begemotSnmpdCommunityEntry 5 }
--
-- Module table
--
begemotSnmpdModuleTable OBJECT-TYPE
SYNTAX SEQUENCE OF BegemotSnmpdModuleEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A table describing all the currently loaded dynamic modules.
Writing to this table loads and unloads modules."
::= { begemotSnmpdObjects 6 }
begemotSnmpdModuleEntry OBJECT-TYPE
SYNTAX BegemotSnmpdModuleEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A table entry describing a loadable module."
INDEX { begemotSnmpdModuleSection }
::= { begemotSnmpdModuleTable 1 }
BegemotSnmpdModuleEntry ::= SEQUENCE {
begemotSnmpdModuleSection SectionName,
begemotSnmpdModulePath OCTET STRING,
begemotSnmpdModuleComment OCTET STRING
}
begemotSnmpdModuleSection OBJECT-TYPE
SYNTAX SectionName
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The string used for matching configuration file sections
and indexes the module table."
::= { begemotSnmpdModuleEntry 1 }
begemotSnmpdModulePath OBJECT-TYPE
SYNTAX OCTET STRING
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The path name of the module. Set to empty string
to unload a module. The path of an existing module
may not be changed."
::= { begemotSnmpdModuleEntry 2 }
begemotSnmpdModuleComment OBJECT-TYPE
SYNTAX OCTET STRING
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"A comment describing this module."
::= { begemotSnmpdModuleEntry 3 }
-- --------------------------------------------------------------------------
--
-- The STATISTICS Group
--
begemotSnmpdStats OBJECT IDENTIFIER ::= { begemotSnmpdObjects 7 }
begemotSnmpdStatsNoRxBufs OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Number of times a receive buffer could not be allocated
for a packet."
::= { begemotSnmpdStats 1 }
begemotSnmpdStatsNoTxBufs OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Number of times a transmit buffer could not be allocated
for a packet."
::= { begemotSnmpdStats 2 }
begemotSnmpdStatsInTooLongPkts OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Number of packets received that were longer than the
receive buffer. These packets are dropped."
::= { begemotSnmpdStats 3 }
begemotSnmpdStatsInBadPduTypes OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Number of packets received with a bad type field."
::= { begemotSnmpdStats 4 }
--
-- The Debug Group
--
begemotSnmpdDebug OBJECT IDENTIFIER ::= { begemotSnmpdObjects 8 }
begemotSnmpdDebugDumpPdus OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Dump PDUs to log file if true."
DEFVAL { false }
::= { begemotSnmpdDebug 1 }
begemotSnmpdDebugSnmpTrace OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Tracing flags for the SNMP library. These flags have the
following meaning:
0x00000001 trace GET operator
0x00000002 trace GETNEXT operator
0x00000004 trace SET operator
0x00000008 trace dependency processing
0x00000010 trace node finding
0x10000000 log ASN1 errors
0x20000000 log SNMP errors
Individual values can be or-ed together."
DEFVAL { 0 }
::= { begemotSnmpdDebug 2 }
begemotSnmpdDebugSyslogPri OBJECT-TYPE
SYNTAX Integer32 (0..8)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Events with this or higher priority should not be logged."
DEFVAL { 7 } -- don't log debug messages
::= { begemotSnmpdDebug 3 }
--
-- Local port table
--
begemotSnmpdLocalPortTable OBJECT-TYPE
SYNTAX SEQUENCE OF BegemotSnmpdLocalPortEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A table with descriptions of local (unix domain) ports to listen
on for SNMP messages."
::= { begemotSnmpdObjects 9 }
begemotSnmpdLocalPortEntry OBJECT-TYPE
SYNTAX BegemotSnmpdLocalPortEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An entry in the table with descriptions of local ports to
listen on for SNMP messages."
INDEX { begemotSnmpdLocalPortPath }
::= { begemotSnmpdLocalPortTable 1 }
BegemotSnmpdLocalPortEntry ::= SEQUENCE {
begemotSnmpdLocalPortPath OCTET STRING,
begemotSnmpdLocalPortStatus INTEGER,
begemotSnmpdLocalPortType INTEGER
}
begemotSnmpdLocalPortPath OBJECT-TYPE
SYNTAX OCTET STRING (SIZE(1..104))
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The path name to create and listen on."
::= { begemotSnmpdLocalPortEntry 1 }
begemotSnmpdLocalPortStatus OBJECT-TYPE
SYNTAX INTEGER { valid(1), invalid(2) }
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"Set status to 1 to create entry, set it to 2 to delete it."
::= { begemotSnmpdLocalPortEntry 2 }
begemotSnmpdLocalPortType OBJECT-TYPE
SYNTAX INTEGER {
dgram-unpriv(1),
dgram-priv(2),
stream-unpriv(3),
stream-priv(4)
}
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"Type of the port. If the type is unpriv SET operations
are allowed from all clients if the community matches. For
priv SET operations are allowed only from peers with uid
zero. If the daemon cannot determine the peer uid it disallows
the SET operation for -priv ports."
::= { begemotSnmpdLocalPortEntry 3 }
--
-- Transport mapping table
--
begemotSnmpdTransportMappings OBJECT IDENTIFIER ::= { begemotSnmpdObjects 10 }
begemotSnmpdTransportTable OBJECT-TYPE
SYNTAX SEQUENCE OF BegemotSnmpdTransportEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A table containing all the currently loaded transport mappings."
::= { begemotSnmpdTransportMappings 1 }
begemotSnmpdTransportEntry OBJECT-TYPE
SYNTAX BegemotSnmpdTransportEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An entry in the table with the transport mappings."
INDEX { begemotSnmpdTransportName }
::= { begemotSnmpdTransportTable 1 }
BegemotSnmpdTransportEntry ::= SEQUENCE {
begemotSnmpdTransportName OCTET STRING,
begemotSnmpdTransportStatus INTEGER,
begemotSnmpdTransportOid OBJECT IDENTIFIER
}
begemotSnmpdTransportName OBJECT-TYPE
SYNTAX OCTET STRING (SIZE(1..256))
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The name of the mapping."
::= { begemotSnmpdTransportEntry 1 }
begemotSnmpdTransportStatus OBJECT-TYPE
SYNTAX RowStatus
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Used to create/activate/destroy the entry."
::= { begemotSnmpdTransportEntry 2 }
begemotSnmpdTransportOid OBJECT-TYPE
SYNTAX OBJECT IDENTIFIER
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"A pointer to the group with the transport-dependend stuff."
::= { begemotSnmpdTransportEntry 3 }
-- ----------------------------------------------------------------------
--
-- Internet port table.
--
BegemotSnmpdTransportProto ::= TEXTUAL-CONVENTION
STATUS current
DESCRIPTION
"A value that represents the type of protocol to be used for
listening on a socket. The following protocols are currently
used:
udp(1) Use UDP for IPv4 and IPv6 sockets."
SYNTAX INTEGER {
udp(1)
}
begemotSnmpdTransInetTable OBJECT-TYPE
SYNTAX SEQUENCE OF BegemotSnmpdTransInetEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This table contains all the ports the daemon should listen on.
Entries can be created at initialization time via the config
file or at run time via a SET. One row can map to several open
sockets in the case of InetAddressType::dns rows. These rows
open one socket for each address returned by getaddrinfo(3).
for SNMP messages."
::= { begemotSnmpdObjects 11 }
begemotSnmpdTransInetEntry OBJECT-TYPE
SYNTAX BegemotSnmpdTransInetEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A row of the internet port table. Each row may map to one or
more listening sockets."
INDEX {
begemotSnmpdTransInetAddressType,
begemotSnmpdTransInetAddress,
begemotSnmpdTransInetPort,
begemotSnmpdTransInetProto
}
::= { begemotSnmpdTransInetTable 1 }
BegemotSnmpdTransInetEntry ::= SEQUENCE {
begemotSnmpdTransInetAddressType InetAddressType,
begemotSnmpdTransInetAddress InetAddress,
begemotSnmpdTransInetPort InetPortNumber,
begemotSnmpdTransInetProto BegemotSnmpdTransportProto,
begemotSnmpdTransInetStatus RowStatus
}
begemotSnmpdTransInetAddressType OBJECT-TYPE
SYNTAX InetAddressType
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The type of the address. Only ipv4, ipv6, ipv6z and dns are
supported."
::= { begemotSnmpdTransInetEntry 1 }
begemotSnmpdTransInetAddress OBJECT-TYPE
SYNTAX InetAddress (SIZE (0..64))
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The address. For ipv4 addresses the length must be 4, ipv6
addresses have a length of 16 and ipv6z addresses a length of
20 where the last four bytes are the interface index in big
endian format. dns addresses may be of zero-length in which case
getaddrinfo() generates INADDR_ANY and its IPv6 equivalent. dns
addresses will open a socket for all addresses returned by
getaddrinfo()."
::= { begemotSnmpdTransInetEntry 2 }
begemotSnmpdTransInetPort OBJECT-TYPE
SYNTAX InetPortNumber (1..65535)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The port to listen on for SNMP messages."
::= { begemotSnmpdTransInetEntry 3 }
begemotSnmpdTransInetProto OBJECT-TYPE
SYNTAX BegemotSnmpdTransportProto
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The protocol to use. Currently only the value udp(1) is supported."
::= { begemotSnmpdTransInetEntry 4 }
begemotSnmpdTransInetStatus OBJECT-TYPE
SYNTAX RowStatus
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The status of the conceptual row. A row may be created using
createAndGo(4) or createAndWait(5). An inactive row can be
activated writing active(1) and an active row can be inactivated
by writing notInService(2). Finally active or inactive rows can be
deleted by writing the value destroy(6). The value of this field
will never read as notReady(3)."
::= { begemotSnmpdTransInetEntry 5 }
--
-- XXX These should go into their own MIB
--
begemotSnmpdTransUdp OBJECT IDENTIFIER ::= { begemotSnmpdTransportMappings 2 }
begemotSnmpdTransLsock OBJECT IDENTIFIER ::= { begemotSnmpdTransportMappings 3 }
begemotSnmpdTransInet OBJECT IDENTIFIER ::= { begemotSnmpdTransportMappings 4 }
END

File diff suppressed because it is too large Load Diff

File diff suppressed because it is too large Load Diff

View File

@ -0,0 +1,60 @@
--
-- Copyright (c) 2001-2003
-- Fraunhofer Institute for Open Communication Systems (FhG Fokus).
-- All rights reserved.
--
-- Author: Harti Brandt <harti@freebsd.org>
--
-- Redistribution and use in source and binary forms, with or without
-- modification, are permitted provided that the following conditions
-- are met:
-- 1. Redistributions of source code must retain the above copyright
-- notice, this list of conditions and the following disclaimer.
-- 2. Redistributions in binary form must reproduce the above copyright
-- notice, this list of conditions and the following disclaimer in the
-- documentation and/or other materials provided with the distribution.
--
-- THIS SOFTWARE IS PROVIDED BY AUTHOR AND CONTRIBUTORS ``AS IS'' AND
-- ANY EXPRESS OR IMPLIED WARRANTIES, INCLUDING, BUT NOT LIMITED TO, THE
-- IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE
-- ARE DISCLAIMED. IN NO EVENT SHALL AUTHOR OR CONTRIBUTORS BE LIABLE
-- FOR ANY DIRECT, INDIRECT, INCIDENTAL, SPECIAL, EXEMPLARY, OR CONSEQUENTIAL
-- DAMAGES (INCLUDING, BUT NOT LIMITED TO, PROCUREMENT OF SUBSTITUTE GOODS
-- OR SERVICES; LOSS OF USE, DATA, OR PROFITS; OR BUSINESS INTERRUPTION)
-- HOWEVER CAUSED AND ON ANY THEORY OF LIABILITY, WHETHER IN CONTRACT, STRICT
-- LIABILITY, OR TORT (INCLUDING NEGLIGENCE OR OTHERWISE) ARISING IN ANY WAY
-- OUT OF THE USE OF THIS SOFTWARE, EVEN IF ADVISED OF THE POSSIBILITY OF
-- SUCH DAMAGE.
--
-- $Begemot: bsnmp/snmpd/FOKUS-MIB.txt,v 1.5 2004/08/06 08:47:08 brandt Exp $
--
-- Begemot private definitions and fokus root.
--
FOKUS-MIB DEFINITIONS ::= BEGIN
IMPORTS
MODULE-IDENTITY, enterprises
FROM SNMPv2-SMI;
fokus MODULE-IDENTITY
LAST-UPDATED "200202050000Z"
ORGANIZATION "Fraunhofer FOKUS, CATS"
CONTACT-INFO
" Hartmut Brandt
Postal: Fraunhofer Institute for Open Communication Systems
Kaiserin-Augusta-Allee 31
10589 Berlin
Germany
Fax: +49 30 3463 7352
E-mail: harti@freebsd.org"
DESCRIPTION
"The root of the Fokus enterprises tree."
REVISION "200202050000Z"
DESCRIPTION
"Initial revision."
::= { enterprises 12325 }
END

View File

@ -0,0 +1,97 @@
-- *****************************************************************
-- This file is in the public domain.
--
-- FreeBSD SMI { enterprises 2238 }
--
-- $FreeBSD$
--
-- *****************************************************************
FREEBSD-MIB DEFINITIONS ::= BEGIN
IMPORTS
MODULE-IDENTITY,
OBJECT-IDENTITY,
enterprises
FROM SNMPv2-SMI;
freeBSD MODULE-IDENTITY
LAST-UPDATED "202009032030Z"
ORGANIZATION "The FreeBSD Project."
CONTACT-INFO
"phk@FreeBSD.org is contact person for this file.
core@FreeBSD.org is the final authority."
DESCRIPTION
"The Structure of Management Information for the
FreeBSD Project enterprise MIB subtree."
REVISION "202009031900Z"
DESCRIPTION
"Added entries for the otherName component of a X.509 cert"
REVISION "200610310800Z"
DESCRIPTION
"Initial version of this MIB module."
::= { enterprises 2238 } -- assigned by IANA
freeBSDsrc OBJECT-IDENTITY
STATUS current
DESCRIPTION
"Subtree for things which lives in the src tree."
::= { freeBSD 1 }
freeBSDsrcCertOtherName OBJECT-IDENTITY
STATUS current
DESCRIPTION
"Subtree for X.509 Certificate otherName entries"
::= { freeBSDsrc 1 }
--
-- For NFS over TLS, a user@domain can optionally be handled by rpc.tlsservd
--
freeBSDsrcCertNFSuser OBJECT-IDENTITY
STATUS current
DESCRIPTION
"Entry for X.509 Certificate for NFS user@domain name"
::= { freeBSDsrcCertOtherName 1 }
freeBSDports OBJECT-IDENTITY
STATUS current
DESCRIPTION
"Subtree for things which lives in the ports tree."
::= { freeBSD 2 }
freeBSDpeople OBJECT-IDENTITY
STATUS current
DESCRIPTION
"Subtree for FreeBSD people.
Under this branch any FreeBSD committer may claim
a subtree. Grab the next sequential oid in the list.
These assignments are not revoked when committers leave
the FreeBSD project.
"
::= { freeBSD 3 }
freeBSDpeoplePhk OBJECT-IDENTITY
STATUS current DESCRIPTION
"Subtree for phk@FreeBSD.org"
::= {freeBSDpeople 1}
freeBSDVersion OBJECT-IDENTITY
STATUS current
DESCRIPTION
"Subtree to register FreeBSD versions. The OID for a FreeBSD
version is formed by appending the dot delimited numbers
from the release number to this base OID. Examples:
5.2.1-STABLE: freeBSDVersion.5.2.1
6.1-STABLE: freeBSDVersion.6.1
7.0-CURRENT: freeBSDVersion.7.0
There is no indication whether this is STABLE or CURRENT.
The sysObjectId is automatically set to the value indicated
by the uname(3) release field by bsnmpd(1). This initial
value can be overwritten in the configuration file."
::= { freeBSD 4 }
END

View File

@ -0,0 +1,325 @@
--
-- Copyright (C) The Internet Society (2005).
--
-- This document is subject to the rights, licenses and restrictions
-- contained in BCP 78, and except as set forth therein, the authors
-- retain all their rights.
--
-- This document and the information contained herein are provided on an
-- "AS IS" basis and THE CONTRIBUTOR, THE ORGANIZATION HE/SHE REPRESENTS
-- OR IS SPONSORED BY (IF ANY), THE INTERNET SOCIETY AND THE INTERNET
-- ENGINEERING TASK FORCE DISCLAIM ALL WARRANTIES, EXPRESS OR IMPLIED,
-- INCLUDING BUT NOT LIMITED TO ANY WARRANTY THAT THE USE OF THE
-- INFORMATION HEREIN WILL NOT INFRINGE ANY RIGHTS OR ANY IMPLIED
-- WARRANTIES OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE.
--
-- $FreeBSD$
--
RSTP-MIB DEFINITIONS ::= BEGIN
-- -------------------------------------------------------------
-- MIB for IEEE 802.1w Rapid Spanning Tree Protocol
-- -------------------------------------------------------------
IMPORTS
MODULE-IDENTITY, OBJECT-TYPE, Integer32, mib-2
FROM SNMPv2-SMI
TruthValue
FROM SNMPv2-TC
MODULE-COMPLIANCE, OBJECT-GROUP
FROM SNMPv2-CONF
dot1dStp, dot1dStpPortEntry
FROM BRIDGE-MIB;
rstpMIB MODULE-IDENTITY
LAST-UPDATED "200512070000Z"
ORGANIZATION "IETF Bridge MIB Working Group"
CONTACT-INFO
"Email: Bridge-mib@ietf.org"
DESCRIPTION
"The Bridge MIB Extension module for managing devices
that support the Rapid Spanning Tree Protocol defined
by IEEE 802.1w.
Copyright (C) The Internet Society (2005). This version of
this MIB module is part of RFC 4318; See the RFC itself for
full legal notices."
REVISION "200512070000Z"
DESCRIPTION
"The initial version of this MIB module as published in
RFC 4318."
::= { mib-2 134 }
-- ---------------------------------------------------------- --
-- subtrees in the RSTP-MIB
-- ---------------------------------------------------------- --
rstpNotifications OBJECT IDENTIFIER ::= { rstpMIB 0 }
rstpObjects OBJECT IDENTIFIER ::= { rstpMIB 1 }
rstpConformance OBJECT IDENTIFIER ::= { rstpMIB 2 }
-- -------------------------------------------------------------
-- Addition to the dot1dStp group
-- -------------------------------------------------------------
dot1dStpVersion OBJECT-TYPE
SYNTAX INTEGER {
stpCompatible(0),
rstp(2)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The version of Spanning Tree Protocol the bridge is
currently running. The value 'stpCompatible(0)'
indicates the Spanning Tree Protocol specified in
IEEE 802.1D-1998 and 'rstp(2)' indicates the Rapid
Spanning Tree Protocol specified in IEEE 802.1w and
clause 17 of 802.1D-2004. The values are directly from
the IEEE standard. New values may be defined as future
versions of the protocol become available.
The value of this object MUST be retained across
reinitializations of the management system."
REFERENCE
"IEEE 802.1w clause 14.8.1, 17.12, 17.16.1"
DEFVAL { rstp }
::= { dot1dStp 16 }
dot1dStpTxHoldCount OBJECT-TYPE
SYNTAX Integer32 (1..10)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The value used by the Port Transmit state machine to limit
the maximum transmission rate.
The value of this object MUST be retained across
reinitializations of the management system."
REFERENCE
"IEEE 802.1w clause 17.16.6"
DEFVAL { 3 }
::= { dot1dStp 17 }
--
-- { dot1dStp 18 } was used to represent dot1dStpPathCostDefault
-- in an earlier version of this MIB. It has since been
-- obsoleted, and should not be used.
--
dot1dStpExtPortTable OBJECT-TYPE
SYNTAX SEQUENCE OF Dot1dStpExtPortEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A table that contains port-specific Rapid Spanning Tree
information."
::= { dot1dStp 19 }
dot1dStpExtPortEntry OBJECT-TYPE
SYNTAX Dot1dStpExtPortEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A list of Rapid Spanning Tree information maintained by
each port."
AUGMENTS { dot1dStpPortEntry }
::= { dot1dStpExtPortTable 1 }
Dot1dStpExtPortEntry ::=
SEQUENCE {
dot1dStpPortProtocolMigration
TruthValue,
dot1dStpPortAdminEdgePort
TruthValue,
dot1dStpPortOperEdgePort
TruthValue,
dot1dStpPortAdminPointToPoint
INTEGER,
dot1dStpPortOperPointToPoint
TruthValue,
dot1dStpPortAdminPathCost
Integer32
}
dot1dStpPortProtocolMigration OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"When operating in RSTP (version 2) mode, writing true(1)
to this object forces this port to transmit RSTP BPDUs.
Any other operation on this object has no effect and
it always returns false(2) when read."
REFERENCE
"IEEE 802.1w clause 14.8.2.4, 17.18.10, 17.26"
::= { dot1dStpExtPortEntry 1 }
dot1dStpPortAdminEdgePort OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The administrative value of the Edge Port parameter. A
value of true(1) indicates that this port should be
assumed as an edge-port, and a value of false(2) indicates
that this port should be assumed as a non-edge-port.
Setting this object will also cause the corresponding
instance of dot1dStpPortOperEdgePort to change to the
same value. Note that even when this object's value
is true, the value of the corresponding instance of
dot1dStpPortOperEdgePort can be false if a BPDU has
been received.
The value of this object MUST be retained across
reinitializations of the management system."
REFERENCE
"IEEE 802.1t clause 14.8.2, 18.3.3"
::= { dot1dStpExtPortEntry 2 }
dot1dStpPortOperEdgePort OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The operational value of the Edge Port parameter. The
object is initialized to the value of the corresponding
instance of dot1dStpPortAdminEdgePort. When the
corresponding instance of dot1dStpPortAdminEdgePort is
set, this object will be changed as well. This object
will also be changed to false on reception of a BPDU."
REFERENCE
"IEEE 802.1t clause 14.8.2, 18.3.4"
::= { dot1dStpExtPortEntry 3 }
dot1dStpPortAdminPointToPoint OBJECT-TYPE
SYNTAX INTEGER {
forceTrue(0),
forceFalse(1),
auto(2)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The administrative point-to-point status of the LAN segment
attached to this port, using the enumeration values of the
IEEE 802.1w clause. A value of forceTrue(0) indicates
that this port should always be treated as if it is
connected to a point-to-point link. A value of
forceFalse(1) indicates that this port should be treated as
having a shared media connection. A value of auto(2)
indicates that this port is considered to have a
point-to-point link if it is an Aggregator and all of its
members are aggregatable, or if the MAC entity
is configured for full duplex operation, either through
auto-negotiation or by management means. Manipulating this
object changes the underlying adminPortToPortMAC.
The value of this object MUST be retained across
reinitializations of the management system."
REFERENCE
"IEEE 802.1w clause 6.4.3, 6.5, 14.8.2"
::= { dot1dStpExtPortEntry 4 }
dot1dStpPortOperPointToPoint OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The operational point-to-point status of the LAN segment
attached to this port. It indicates whether a port is
considered to have a point-to-point connection.
If adminPointToPointMAC is set to auto(2), then the value
of operPointToPointMAC is determined in accordance with the
specific procedures defined for the MAC entity concerned,
as defined in IEEE 802.1w, clause 6.5. The value is
determined dynamically; that is, it is re-evaluated whenever
the value of adminPointToPointMAC changes, and whenever
the specific procedures defined for the MAC entity evaluate
a change in its point-to-point status."
REFERENCE
"IEEE 802.1w clause 6.4.3, 6.5, 14.8.2"
::= { dot1dStpExtPortEntry 5 }
dot1dStpPortAdminPathCost OBJECT-TYPE
SYNTAX Integer32 (0..200000000)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The administratively assigned value for the contribution
of this port to the path cost of paths toward the spanning
tree root.
Writing a value of '0' assigns the automatically calculated
default Path Cost value to the port. If the default Path
Cost is being used, this object returns '0' when read.
This complements the object dot1dStpPortPathCost or
dot1dStpPortPathCost32, which returns the operational value
of the path cost.
The value of this object MUST be retained across
reinitializations of the management system."
REFERENCE
"IEEE 802.1D-1998: Section 8.5.5.3"
::= { dot1dStpExtPortEntry 6 }
-- -------------------------------------------------------------
-- rstpMIB - Conformance Information
-- -------------------------------------------------------------
rstpGroups OBJECT IDENTIFIER ::= { rstpConformance 1 }
rstpCompliances OBJECT IDENTIFIER ::= { rstpConformance 2 }
-- -------------------------------------------------------------
-- Units of conformance
-- -------------------------------------------------------------
rstpBridgeGroup OBJECT-GROUP
OBJECTS {
dot1dStpVersion,
dot1dStpTxHoldCount
}
STATUS current
DESCRIPTION
"Rapid Spanning Tree information for the bridge."
::= { rstpGroups 1 }
rstpPortGroup OBJECT-GROUP
OBJECTS {
dot1dStpPortProtocolMigration,
dot1dStpPortAdminEdgePort,
dot1dStpPortOperEdgePort,
dot1dStpPortAdminPointToPoint,
dot1dStpPortOperPointToPoint,
dot1dStpPortAdminPathCost
}
STATUS current
DESCRIPTION
"Rapid Spanning Tree information for individual ports."
::= { rstpGroups 2 }
-- -------------------------------------------------------------
-- Compliance statements
-- -------------------------------------------------------------
rstpCompliance MODULE-COMPLIANCE
STATUS current
DESCRIPTION
"The compliance statement for device support of Rapid
Spanning Tree Protocol (RSTP) bridging services."
MODULE
MANDATORY-GROUPS {
rstpBridgeGroup,
rstpPortGroup
}
::= { rstpCompliances 1 }
END

View File

@ -0,0 +1,48 @@
apiVersion: apps/v1
kind: Deployment
metadata:
name: snmp-exporter
spec:
selector:
matchLabels:
app.kubernetes.io/name: snmp-exporter
template:
metadata:
labels:
app.kubernetes.io/name: snmp-exporter
spec:
containers:
- name: snmp-exporter
image: prom/snmp-exporter
resources:
requests:
memory: 128Mi
cpu: 100m
limits:
memory: 128Mi
cpu: 100m
ports:
- containerPort: 9116
name: http-metrics
volumeMounts:
- name: exporter-config
mountPath: /etc/snmp_exporter/snmp.yml
subPath: snmp.yml
volumes:
- name: exporter-config
configMap:
name: exporter-config
---
apiVersion: v1
kind: Service
metadata:
name: snmp-exporter
labels:
app.kubernetes.io/name: snmp-exporter
spec:
selector:
app.kubernetes.io/name: snmp-exporter
ports:
- name: http-metrics
port: 9116
targetPort: http-metrics

View File

@ -10,6 +10,7 @@ resources:
- ../../overlays/home-assistant
- ../../overlays/jellyfin
- ../../overlays/deluge
- probes/snmp-exporter.yaml
# resources:
# - probes/external-services-bobcat-miner.yaml
@ -38,7 +39,7 @@ images:
- name: nextcloud/aio-imaginary
newTag: 20230613_120442-latest-arm64
- name: homeassistant/home-assistant
newTag: 2023.9.2
newTag: 2023.10.2
- name: jellyfin/jellyfin
newTag: 10.8.10
- name: lscr.io/linuxserver/deluge

View File

@ -1,18 +0,0 @@
apiVersion: monitoring.coreos.com/v1
kind: Probe
metadata:
name: blackbox-exporter-bobcat-miner
labels:
app.kubernetes.io/name: blackbox-exporter
monitor: prometheus
namespace: monitoring
spec:
module: icmp
prober:
url: blackbox-exporter.monitoring.svc:9115
targets:
staticConfig:
static:
- 192.168.40.30
labels:
service: bobcat-miner

View File

@ -0,0 +1,22 @@
apiVersion: monitoring.coreos.com/v1
kind: Probe
metadata:
name: snmp-exporter-pfsense
labels:
app.kubernetes.io/name: snmp-exporter
monitor: prometheus
namespace: monitoring
spec:
module: pfsense
prober:
url: snmp-exporter.monitoring.svc:9116
path: snmp
targets:
staticConfig:
static:
- 192.168.20.1
metricRelabelings:
- sourceLabels: [__name__]
replacement: pfsense_$1
targetLabel: __name__

View File

@ -4,6 +4,7 @@ resources:
- ../../bases/prometheus
# - ../../bases/node-exporter
- ../../bases/blackbox-exporter
- ../../bases/snmp-exporter
# - ../../bases/ecommerce-exporter
- ../../bases/kube-state-metrics
- ../../bases/grafana-agent